Add raid10 doco to mdadm.8
Signed-off-by: Neil Brown <neilb@cse.unsw.edu.au>
This commit is contained in:
parent
a9d69660a3
commit
1a7dfc3550
43
mdadm.8
43
mdadm.8
|
@ -30,6 +30,7 @@ md devices,
|
||||||
.BR RAID4 ,
|
.BR RAID4 ,
|
||||||
.BR RAID5 ,
|
.BR RAID5 ,
|
||||||
.BR RAID6 ,
|
.BR RAID6 ,
|
||||||
|
.BR RAID10 ,
|
||||||
.BR MULTIPATH ,
|
.BR MULTIPATH ,
|
||||||
and
|
and
|
||||||
.BR FAULTY .
|
.BR FAULTY .
|
||||||
|
@ -123,7 +124,7 @@ superblocks, erasing old superblocks and stopping active arrays.
|
||||||
.TP
|
.TP
|
||||||
.B "Follow or Monitor"
|
.B "Follow or Monitor"
|
||||||
Monitor one or more md devices and act on any state changes. This is
|
Monitor one or more md devices and act on any state changes. This is
|
||||||
only meaningful for raid1, 4, 5, 6 or multipath arrays as
|
only meaningful for raid1, 4, 5, 6, 10 or multipath arrays as
|
||||||
only these have interesting state. raid0 or linear never have
|
only these have interesting state. raid0 or linear never have
|
||||||
missing, spare, or failed drives, so there is nothing to monitor.
|
missing, spare, or failed drives, so there is nothing to monitor.
|
||||||
|
|
||||||
|
@ -340,24 +341,28 @@ Specify rounding factor for linear array (==chunk size)
|
||||||
Set raid level. When used with
|
Set raid level. When used with
|
||||||
.IR --create ,
|
.IR --create ,
|
||||||
options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
|
options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
|
||||||
raid5, 5, raid6, 6, multipath, mp, fautly. Obviously some of these are synonymous.
|
raid5, 5, raid6, 6, raid10, 10, multipath, mp, fautly. Obviously some of these are synonymous.
|
||||||
|
|
||||||
When used with
|
When used with
|
||||||
.IR --build ,
|
.IR --build ,
|
||||||
only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
|
only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
|
||||||
|
|
||||||
.TP
|
.TP
|
||||||
.BR -p ", " --parity=
|
.BR -p ", " --layout=
|
||||||
Set raid5 parity algorithm. Options are:
|
This option configures the fine details of data layout for raid5,
|
||||||
|
and raid10 arrays, and controls the failure modes for
|
||||||
|
.IR faulty .
|
||||||
|
|
||||||
|
The layout of the raid5 parity block can be one of
|
||||||
left-asymmetric,
|
left-asymmetric,
|
||||||
left-symmetric,
|
left-symmetric,
|
||||||
right-asymmetric,
|
right-asymmetric,
|
||||||
right-symmetric,
|
right-symmetric,
|
||||||
la, ra, ls, rs. The default is left-symmetric.
|
la, ra, ls, rs. The default is left-symmetric.
|
||||||
|
|
||||||
This option is also used to set the failure mode for
|
When setting the failure mode for
|
||||||
.IR faulty .
|
.I faulty
|
||||||
The options are:
|
the options are:
|
||||||
write-transient,
|
write-transient,
|
||||||
wt,
|
wt,
|
||||||
read-transient,
|
read-transient,
|
||||||
|
@ -388,9 +393,27 @@ and "flush" will clear any persistant faults.
|
||||||
To set the parity with "--grow", the level of the array ("faulty")
|
To set the parity with "--grow", the level of the array ("faulty")
|
||||||
must be specified before the fault mode is specified.
|
must be specified before the fault mode is specified.
|
||||||
|
|
||||||
|
Finally, the layout options for RAID10 are either 'n' or 'p' followed
|
||||||
|
by a small number. The default is 'n2'.
|
||||||
|
|
||||||
|
.I n
|
||||||
|
signals 'near' copies (multiple copies of one data block are at
|
||||||
|
similar offsets in different devices) while
|
||||||
|
.I f
|
||||||
|
signals 'far' copies
|
||||||
|
(multiple copies have very different offsets). See md(4) for more
|
||||||
|
detail about 'near' and 'far'.
|
||||||
|
|
||||||
|
The number is the number of copies of each datablock. 2 is normal, 3
|
||||||
|
can be useful. This number can be at most equal to the number of
|
||||||
|
devices in the array. It does not need to divide evenly into that
|
||||||
|
number (e.g. it is perfectly legal to have an 'n2' layout for an array
|
||||||
|
with an odd number of devices).
|
||||||
|
|
||||||
.TP
|
.TP
|
||||||
.BR --layout=
|
.BR --parity=
|
||||||
same as --parity
|
same as --layout (thus explaining the p of
|
||||||
|
.IR -p ).
|
||||||
|
|
||||||
.TP
|
.TP
|
||||||
.BR -b ", " --bitmap=
|
.BR -b ", " --bitmap=
|
||||||
|
@ -839,7 +862,7 @@ Normally the array will be started after it is assembled. However if
|
||||||
is not given and insufficient drives were listed to start a complete
|
is not given and insufficient drives were listed to start a complete
|
||||||
(non-degraded) array, then the array is not started (to guard against
|
(non-degraded) array, then the array is not started (to guard against
|
||||||
usage errors). To insist that the array be started in this case (as
|
usage errors). To insist that the array be started in this case (as
|
||||||
may work for RAID1, 4, 5 or 6), give the
|
may work for RAID1, 4, 5, 6, or 10), give the
|
||||||
.B --run
|
.B --run
|
||||||
flag.
|
flag.
|
||||||
|
|
||||||
|
|
Loading…