Manage: Add support for --re-add faulty
mdadm /dev/mdXX --re-add faulty will identify any faulty devices in the array, remove them, and --re-add them. Signed-off-by: NeilBrown <neilb@suse.de>
This commit is contained in:
parent
5fe7f5f7c8
commit
262e3b7fe8
17
Manage.c
17
Manage.c
|
@ -1084,6 +1084,8 @@ int Manage_subdevs(char *devname, int fd,
|
|||
* it must be unpaired, and is an error.
|
||||
* 'M' - this is created by a 'missing' target. It is a slight
|
||||
* variant on 'A'
|
||||
* 'F' - Another variant of 'A', where the device was faulty
|
||||
* so must be removed from the array first.
|
||||
*
|
||||
* For 'f' and 'r', the device can also be a kernel-internal
|
||||
* name such as 'sdb'.
|
||||
|
@ -1128,13 +1130,15 @@ int Manage_subdevs(char *devname, int fd,
|
|||
|
||||
if (strcmp(dv->devname, "failed") == 0 ||
|
||||
strcmp(dv->devname, "faulty") == 0) {
|
||||
if (dv->disposition != 'r') {
|
||||
if (dv->disposition != 'A'
|
||||
&& dv->disposition != 'r') {
|
||||
pr_err("%s only meaningful "
|
||||
"with -r, not -%c\n",
|
||||
"with -r or --re-add, not -%c\n",
|
||||
dv->devname, dv->disposition);
|
||||
goto abort;
|
||||
}
|
||||
add_faulty(dv, fd, 'r');
|
||||
add_faulty(dv, fd, (dv->disposition == 'A'
|
||||
? 'F' : 'r'));
|
||||
continue;
|
||||
}
|
||||
if (strcmp(dv->devname, "detached") == 0) {
|
||||
|
@ -1245,7 +1249,8 @@ int Manage_subdevs(char *devname, int fd,
|
|||
goto abort;
|
||||
case 'a':
|
||||
case 'A':
|
||||
case 'M':
|
||||
case 'M': /* --re-add missing */
|
||||
case 'F': /* --re-add faulty */
|
||||
/* add the device */
|
||||
if (subarray) {
|
||||
pr_err("Cannot add disks to a"
|
||||
|
@ -1253,6 +1258,10 @@ int Manage_subdevs(char *devname, int fd,
|
|||
" operation on the parent container\n");
|
||||
goto abort;
|
||||
}
|
||||
if (dv->disposition == 'F')
|
||||
/* Need to remove first */
|
||||
ioctl(fd, HOT_REMOVE_DISK,
|
||||
(unsigned long)stb.st_rdev);
|
||||
/* Make sure it isn't in use (in 2.6 or later) */
|
||||
tfd = dev_open(dv->devname, O_RDONLY|O_EXCL);
|
||||
if (tfd >= 0) {
|
||||
|
|
14
mdadm.8.in
14
mdadm.8.in
|
@ -1260,9 +1260,21 @@ explanation of their use.
|
|||
|
||||
If the device name given is
|
||||
.B missing
|
||||
then mdadm will try to find any device that looks like it should be
|
||||
then
|
||||
.I mdadm
|
||||
will try to find any device that looks like it should be
|
||||
part of the array but isn't and will try to re\-add all such devices.
|
||||
|
||||
If the device name given is
|
||||
.B faulty
|
||||
then
|
||||
.I mdadm
|
||||
will find all devices in the array that are marked
|
||||
.BR faulty ,
|
||||
remove them and attempt to immediately re\-add them. This can be
|
||||
useful if you are certain that the reason for failure has been
|
||||
resolved.
|
||||
|
||||
.TP
|
||||
.BR \-r ", " \-\-remove
|
||||
remove listed devices. They must not be active. i.e. they should
|
||||
|
|
Loading…