imsm: fix num_domains
The 'num_domains' field simply identifies the number of mirrors. So it is 2 for a 2-disk raid1 or a 4-disk raid10. The orom does not currently support more than 2 mirrors, but a three disk raid1 for example would increase num_domains to 3. Signed-off-by: Dan Williams <dan.j.williams@intel.com>
This commit is contained in:
parent
222a7bfd2e
commit
81062a36ab
|
@ -2405,13 +2405,16 @@ static int init_super_imsm_volume(struct supertype *st, mdu_array_info_t *info,
|
|||
"in a raid1 volume\n");
|
||||
return 0;
|
||||
}
|
||||
|
||||
map->raid_level = info->level;
|
||||
if (info->level == 10) {
|
||||
map->raid_level = 1;
|
||||
map->num_domains = info->raid_disks / 2;
|
||||
} else {
|
||||
map->raid_level = info->level;
|
||||
} else if (info->level == 1)
|
||||
map->num_domains = info->raid_disks;
|
||||
else
|
||||
map->num_domains = 1;
|
||||
}
|
||||
|
||||
num_data_stripes = info_to_num_data_stripes(info, map->num_domains);
|
||||
map->num_data_stripes = __cpu_to_le32(num_data_stripes);
|
||||
|
||||
|
|
Loading…
Reference in New Issue